關於高(gāo)效過濾(lǜ)器的更換周期(qī)方麵的問題,很(hěn)多潔淨室(shì)用(yòng)戶(hù)都很關心,畢竟高效過(guò)濾器決定著(zhe)潔淨室的潔淨度能否達到標準(zhǔn),就在前方草莓秋葵菠萝蜜黄瓜榴莲视频也整理過相關方麵的問題:高效過濾器的更換標準

In the pharmaceutical industry, HEPA filters are used as terminal filters for the processing or filtration of air in production spaces. They are mandatory in sterile production, although they are sometimes also used in the manufacture of solid or semisolid dosage forms. Amongst the HEPA or high-efficiency particulate air filters are Filter Classes H13 to H14 (DIN 1822), the latter with a retention rate of 99.995%. But how often do they need to be changed?

在製藥行業,高效過(guò)濾器(HEPA)用於(yú)生產空間空(kōng)氣的處理和過濾的終端過濾(lǜ)器。無菌(jun1)生(shēng)產要求強製使用高效過濾器,而固體和半固(gù)體(tǐ)劑型的生產有時也會使用。H13至H14(DIN1822)是高效過濾器的兩種(zhǒng),後者截留率為99.995%。但多久必(bì)須更換一次(cì)呢?

One can frequently find internal company guidelines according to which the filters should be changed annually, regardless of monitoring results. Is that sensible? An exact number, meaning the maximum duration of use for HEPA filters in months, cannot be found in the relevant GMP guidelines. According to GMP, the filter has to be free of leaks. This is verified by qualification and regularly performed leak tests as per ISO 14644-3, which are mandatory for sterile facilities. According to the technical 參考:(www.ljinghua.com)interpretation of the Annex 1 (PIC/S PI 032-2), leak tests are to be performed every six months in A/B zones and every twelve months in C/D zones. The FDA Aseptic Guide demands a regular inspection. The requirements of Annex 1 can be applied here as well. Leaks may be repaired; those repaired areas may only take up 0.5% of the filter surface per filter.

製藥廠高(gāo)效過濾器一般多久更換(huàn)?

草莓秋葵菠萝蜜黄瓜榴莲视频經常看到(dào)在公司內部文件中,要求每年更換過濾器,而不管檢測結果(guǒ)如何。這是否合理?在相關的GMP指南中並沒有高效過濾器可以使(shǐ)用期限的(de)具體數值。根據GMP的要求,過濾器不得有泄漏,這需要通過(guò)確認(rèn)和定期執行ISO14644-3中(zhōng)的泄漏測試,無菌車間(jiān)來說這(zhè)是必(bì)須的(de)。根據附錄1(PIC/S PI032-2)的技術詮釋,A/B級每6個月進行泄漏測試,C/D級則為12個月。FDA無菌指南要(yào)求進行定期檢查。附錄1的要求在這裏也適用。泄漏是可以(yǐ)修補的,但修補的麵積不能超過單個過濾器麵(miàn)積(jī)的0.5%。)

However, not only the integrity of the HEPA filter is relevant. The load of the filter (layer) and thus the pressure drop at the filter is also important. If the pressure drop at the filter rises, the energy demand of the ventilation system increases to maintain the necessary air change rates. This pressure drop at the filter can increase to the performance limits of the ventilation system. To protect the HEPA filters, preliminary filters are used - usually fine particulate air filters like F7 und F9 filters (EN779). Those have to be replaced regularly and protect the HEPA filters from clogging.

當然,廣州靈潔(jié)淨(jìng)化高效(xiào)過濾器並不隻有完整(zhěng)性一件事情。過濾器(層)的負載以及上下(xià)遊壓差也(yě)很重要。如果過(guò)濾器上下遊壓差升高,則送排風係統的能量需求會增加,這樣才能維持必須的換氣次數。這樣的過濾器上下遊壓差可能(néng)會增加通風(fēng)係(xì)統的性能限製。為了保護高效過濾(lǜ)器,就要使用前端過濾器---通常是像F7和F9過濾器(EN779)這樣(yàng)的精細過濾器。這些過濾器必須定期更換以保護高效過(guò)濾器避免堵塞

From a practical viewpoint, one could say that the maximum duration of use depends directly on the pressure drop. Changing the filters only makes sense if the pressure drop gets too high for the performance of the ventilation system or if the cost of energy demand lies above the cost of a filter change. The filters do have to pass the leak tests (see above), of course. In practice, several companies do not use a filter for more than eight years. As mentioned before, though, this is not a legally binding value, but merely based on experience.

從實踐角度來看,草莓秋葵菠萝蜜黄瓜榴莲视频可以說(shuō)最長使用期限直接取決於上下遊壓差。隻有在上下遊壓差達到一定數值影響(xiǎng)到通風係統的性能,或者是能量需(xū)求超過過濾器更換成本時,過濾器更換才有意義。但是,過濾器必須能通過(guò)泄漏(lòu)測試(如上所述)。事實上,很多公司並不會(huì)使用一(yī)個過(guò)濾器超過8年。正如前述,並沒有法規規定這(zhè)樣(yàng)的值,這都(dōu)隻是根據經驗(yàn)得來(lái)的。

靈潔高效過濾器更換問題

谘詢內容:老師您好,小容(róng)量注射劑車間空調係統的高效過濾器必須定期更換嗎(ma)?如不(bú)定期更換(huàn),隻在空調驗證時更換風量不合格房間高效和(hé)撿(jiǎn)漏不(bú)合格高效可以嗎?

CFDA審核查驗中心回複:你好(hǎo),更換高效過濾器根據空(kōng)調驗證參考:時風量和撿(jiǎn)漏是必須的,但同時也應製定出具體高效過濾器最長使用周期,故還是應該有定期的概念。同時(shí)必須定期進(jìn)行過濾器完整性測試。

製藥廠高效過濾器一般多久更換?

潔淨區A級(jí)高效過濾器檢漏

谘詢內容:潔淨區A級高效過濾(lǜ)器檢(jiǎn)漏是否可以使用 塵埃粒子計數器 掃描檢漏(lòu),如果可以,那麽判斷無泄漏的標準是多少。

CFDA審核查驗中心回複:靈潔高效過濾器檢(jiǎn)漏一般(bān)在非關鍵區域可以使用塵埃粒子計數器,但A級潔淨區高效過濾器不推薦使用塵埃粒子計(jì)數器掃描檢漏


本文網(wǎng)址:http://www.hrbpf.com/product/645.html

關鍵詞:藥(yào)廠高效過濾器,製藥高效過濾器,潔淨室高效過濾器

最近瀏覽:

在線留言
您的姓名:
您的電話:
留言內容:
聯係草莓秋葵菠萝蜜黄瓜榴莲视频

聯(lián)  係 人:龔經理

電      話:13710142110

傳      真:020-84550845

郵      編:510000

網(wǎng)      址:www.hrbpf.com

郵      箱:lingjie@gdlingjie.com 

地      址:廣東省廣州市番禺(yú)區石(shí)基鎮進盈工業園A區E座



二維碼

111111.png

Copyright 2018,廣州靈潔空氣淨(jìng)化設備官方(fāng)網站版權(quán)所有   備案號:粵ICP備12000047號-6   技術支持:廣州靈潔

  • 在線客服
  • 在線留言
  • 手機網站
  • 在線谘(zī)詢
    歡迎給草莓秋葵菠萝蜜黄瓜榴莲视频留言(yán)
    請(qǐng)在此(cǐ)輸入留言內容,草莓秋葵菠萝蜜黄瓜榴莲视频會盡快與您聯係。
    姓名
    聯係人
    電話
    座機/手機號碼(mǎ)
    郵箱
    郵箱
    地址
    地(dì)址
    网站地图 草莓秋葵菠萝蜜黄瓜榴莲视频_榴莲视频下载_榴莲视频色版_榴莲app官网下载1.0.3