初效過(guò)濾器、中(zhōng)效過(guò)濾器、高效過濾器、淨化設備(bèi)專業生產廠(chǎng)家(國家技術企業(yè))歡迎您!

服務熱線:4008-727374

空氣過濾器

鷹潭製藥廠高效過(guò)濾器

  • 所屬分類:鷹潭高效過濾器(qì)

  • 點(diǎn)擊次數:
  • 發布日期:2020/11/26
  • 在線詢價
詳細介紹

關於高效過濾器的更換周期方麵的問題,很多潔淨室用戶都很關心,畢竟高(gāo)效(xiào)過(guò)濾(lǜ)器決定著潔淨室的潔淨度能否達到標準,就在前方草莓秋葵菠萝蜜黄瓜榴莲视频也整理過相關(guān)方麵的問(wèn)題:高效過濾器的更換(huàn)標(biāo)準(zhǔn)

In the pharmaceutical industry, HEPA filters are used as terminal filters for the processing or filtration of air in production spaces. They are mandatory in sterile production, although they are sometimes also used in the manufacture of solid or semisolid dosage forms. Amongst the HEPA or high-efficiency particulate air filters are Filter Classes H13 to H14 (DIN 1822), the latter with a retention rate of 99.995%. But how often do they need to be changed?

在(zài)製藥行業,高效過濾器(HEPA)用於生產空間空氣的(de)處理和過濾的終(zhōng)端過濾器。無菌生(shēng)產要求強製(zhì)使用高效(xiào)過濾器(qì),而固(gù)體和半固體劑型(xíng)的生產有時也會使用。H13至H14(DIN1822)是高效過濾器的兩種,後者截留率為99.995%。但多久必須更換一次呢?

One can frequently find internal company guidelines according to which the filters should be changed annually, regardless of monitoring results. Is that sensible? An exact number, meaning the maximum duration of use for HEPA filters in months, cannot be found in the relevant GMP guidelines. According to GMP, the filter has to be free of leaks. This is verified by qualification and regularly performed leak tests as per ISO 14644-3, which are mandatory for sterile facilities. According to the technical 參考:(www.ljinghua.com)interpretation of the Annex 1 (PIC/S PI 032-2), leak tests are to be performed every six months in A/B zones and every twelve months in C/D zones. The FDA Aseptic Guide demands a regular inspection. The requirements of Annex 1 can be applied here as well. Leaks may be repaired; those repaired areas may only take up 0.5% of the filter surface per filter.

製藥廠高效過濾器一般多久更換?

草莓秋葵菠萝蜜黄瓜榴莲视频(men)經(jīng)常看到在公司內部文件中,要求每年更換(huàn)過濾器(qì),而不管檢測結果如何。這是否合理?在相關的GMP指(zhǐ)南中並沒有(yǒu)高效過濾(lǜ)器可以使用期限的(de)具(jù)體數值。根據GMP的要求,過(guò)濾器(qì)不得有泄漏,這需(xū)要(yào)通過確認和定期執行ISO14644-3中的泄漏測試,無菌(jun1)車間來(lái)說這是(shì)必須的。根據附錄1(PIC/S PI032-2)的技術詮釋,A/B級每6個月進行(háng)泄漏測試,C/D級則為12個月。FDA無菌指南要求進行定期檢查。附錄1的要(yào)求在這裏也適(shì)用。泄漏是可(kě)以修補的,但修補(bǔ)的麵(miàn)積不能超過單個過濾器麵積的(de)0.5%。)

However, not only the integrity of the HEPA filter is relevant. The load of the filter (layer) and thus the pressure drop at the filter is also important. If the pressure drop at the filter rises, the energy demand of the ventilation system increases to maintain the necessary air change rates. This pressure drop at the filter can increase to the performance limits of the ventilation system. To protect the HEPA filters, preliminary filters are used - usually fine particulate air filters like F7 und F9 filters (EN779). Those have to be replaced regularly and protect the HEPA filters from clogging.

當然,廣州靈潔淨化高效過濾器並不隻有完整性一件事情。過濾器(層)的負載以及上下遊壓差也(yě)很重要。如果過濾器上下遊壓差升高,則送排(pái)風係統的能量需求會增加,這(zhè)樣才能維(wéi)持必須的(de)換氣次數。這樣的過濾器上下遊壓差可能會增加通(tōng)風(fēng)係統的性能限製。為了保護高效過濾器,就要使用前(qián)端(duān)過濾器---通常是(shì)像F7和F9過濾器(EN779)這樣的精(jīng)細過濾器(qì)。這些(xiē)過濾器必須定期更換以保護高效過濾器避免堵塞

From a practical viewpoint, one could say that the maximum duration of use depends directly on the pressure drop. Changing the filters only makes sense if the pressure drop gets too high for the performance of the ventilation system or if the cost of energy demand lies above the cost of a filter change. The filters do have to pass the leak tests (see above), of course. In practice, several companies do not use a filter for more than eight years. As mentioned before, though, this is not a legally binding value, but merely based on experience.

從實踐角度來看,草莓秋葵菠萝蜜黄瓜榴莲视频可以說(shuō)最長使用期限直接取決於上下遊(yóu)壓差。隻有在上下(xià)遊壓差達(dá)到(dào)一定數值影響到通風係統的性能,或者是(shì)能量需求超過(guò)過(guò)濾器更(gèng)換(huàn)成本時,過濾器更換才有意義。但是,過濾器必須能通過泄漏測試(如上所述)。事實上,很多公司並不會使(shǐ)用一個過濾器(qì)超過8年(nián)。正如前述,並沒有法規規定這樣的(de)值,這都隻是根據經驗得來(lái)的。

靈潔高效過濾器更換問題

谘詢內容:老師您好,小(xiǎo)容量注射劑車間空調係(xì)統(tǒng)的高效過濾器必須(xū)定期更換嗎?如不定期更換(huàn),隻(zhī)在空調驗證時更換風量不合格房間高效和撿漏不合格高效可以嗎?

CFDA審核查驗中心回複:你(nǐ)好,更換高效過濾器根據空調驗證參考:時風量和撿漏是必須的,但同時也應製定出具(jù)體高效過濾器最長使用周期,故還是應該有(yǒu)定期(qī)的概念。同時必須定期進行過濾器完整性(xìng)測試。

製藥廠高效過濾器一般多久更換?

潔淨區A級高效過濾器檢漏

谘詢內容:潔(jié)淨區A級(jí)高效過濾器檢漏是(shì)否(fǒu)可以使用 塵埃粒子計數器(qì) 掃描檢漏(lòu),如果可以,那麽判斷無泄漏的標準是多少。

CFDA審核查驗中心回(huí)複:靈潔高效過濾器(qì)檢漏一般在非關鍵區域可以使用塵埃粒子計數器,但A級潔淨區高(gāo)效過濾器不推薦使用(yòng)塵埃粒子計數(shù)器掃描檢漏


本文網址:http://www.hrbpf.com/product/645.html

關鍵詞:藥廠高效過濾器(qì),製藥高(gāo)效過濾器,潔淨室(shì)高效過(guò)濾器

最近瀏覽:

在線留言
您的姓(xìng)名:
您的電話:
留言(yán)內容:
聯係草莓秋葵菠萝蜜黄瓜榴莲视频

聯  係 人:龔經理

電      話(huà):13710142110

傳(chuán)      真:020-84550845

郵      編:510000

網      址(zhǐ):www.hrbpf.com

郵      箱:lingjie@gdlingjie.com 

地      址:廣東省廣州市番禺區石基鎮進盈工業園A區E座



二維碼(mǎ)

111111.png

Copyright 2018,廣州靈潔空(kōng)氣淨化設備官方網站版權(quán)所有(yǒu)   備(bèi)案號:粵ICP備12000047號-6   技術支持:廣州靈潔

  • 在線客服
  • 聯係電話
    13829746856
  • 在線留言
  • 手機網站(zhàn)
  • 在(zài)線谘詢
    歡迎給草莓秋葵菠萝蜜黄瓜榴莲视频留言
    請在此輸入留言內容,我(wǒ)們會盡快與您聯係。
    姓名
    聯係人
    電話
    座機/手機號(hào)碼
    郵箱
    郵箱
    地址
    地址
    网站地图 草莓秋葵菠萝蜜黄瓜榴莲视频_榴莲视频下载_榴莲视频色版_榴莲app官网下载1.0.3